贮存/工作环境温度与试验温度之间的关系

请教下:在进行高温贮存/工作试验或低温贮存/工作试验时,试样样品的贮存/工作环境温度与试验温度之间是什么关系?

给TA打赏
共{{data.count}}人
人已打赏
可靠性技术新手提问

谁有欧斯朗、飞利浦等LED的可靠性认证报告,分享下,谢谢!

2012-3-1 19:44:27

可靠性技术可靠性试验

温度循环的几个问题

2012-3-2 13:59:49

3 条回复 A文章作者 M管理员
  1. lion_lkm

    —AmbientTemperature(Ta).Ambienttemperatureistheroom
    temperatureoroutsideairtemperaturewhentheunitisoperatingunder
    normalconditions3.GR-63-CORE,NEBSTMRequirements:Physical
    Protection,specifiesaroomambientairtemperatureof23°C(73°F)
    measured1.5m(59in)abovethefloorand400mm(15.8in)infrontofthe
    equipment.A25°Cambienttemperaturemaybeusedastheairintaketothe
    equipmentcontainingtheunit.Foroutdoornaturalconvectioncooled
    equipment,ambienttemperatureisdefinedastheoutsideairtemperature
    (includingtheeffectsofsolarloading)outsidetheunitbasedonthespecific
    application.
    —DeviceOperatingTemperature.Operatingtemperatureforadeviceisthe
    temperatureinsidetheunitinwhichthedeviceresides.Thistemperatureis
    definedasthetemperature0.5inchabovethesurfaceofthedevice.When
    temperaturevariationsacrosstheboardarerelativelyconstant(asinforced
    aircooledsystems),theaverageboardtemperaturemaybeused.Board
    temperaturemaybedeterminedbytemperaturesensors,thermocouple
    measurements,computersimulations,orInfrared(IR)imaging.When
    temperaturesacrosstheboardvarysignificantly(asinconvectioncooled
    equipment),devicecasetemperaturesmaybeusedforthemajorhighheat
    dissipatingdevicesandtheaverageboardtemperatureforallotherdevices.
    •UsageExample:Thenormalizeddeviceoperatingtemperatureof40°C
    assumesa25°Cambienttemperatureplusa15°Caverageboard
    temperatureriseduetolocalheatgeneration.
    —CaseTemperatures(Tc).Casetemperatureistheexternaldevice
    temperaturemeasuredoutsidethedevice’scase.Thecasetemperatureof
    majorheatdissipatingdevicesmaybeusedtodeterminetheoperating
    temperatureforthesedevices.
    •UsageExample:Thermalmappingofapowertransistorshowsanaverage
    casetemperatureof70°C,withanaverageboardtemperatureof50°Cfor
    allotherdevices.
    —JunctionTemperatures(Tj).JunctionTemperaturescannotbeused
    directlywithTable9-1todetermineaTemperatureFactor,sinceTable9-1is
    calibratedtodeviceoperatingtemperatureorcasetemperatureasdefined
    above.Tjcanonlybeusedtodeterminefailureratewhenadevice
    manufacturerprovidesaprovenJunctionTemperature-FailureRateModel.

  2. reliab

    [b]回复[url=pid=99197&ptid=12030]1#[/url][i]wwd0809[/i][/b]

    问题有点描述不清!太含糊让人无法回答