EIAJED-4701系列标准
[quote]StandardofJapanElectronicsandInformationTechnologyIndustriesAssociation
EIAJED-4701/100
Environmentalandendurancetestmethodsfor
semiconductordevices
(LifetestI)
EIAJED-4701/100
TESTMETHOD101
STEADYSTATEOPERATINGLIFE
1.SCOPE
Thisstandardprovidesforthemethodtoevaluatetheenduranceofsemiconductordeviceswhentheyaresubmittedtoelectricstressandthermalstressoflongduration.
Remarks:
Caremustbetakenwhenexecutingthistest,becausethedevicetemperaturemayexceedtheambientpresettemperatureandriseconspicuouslyduetointernallydissipatedheatfromthedevice.
2.TESTEQUIPMENT
Equipmenttobeusedinthistestshouldconsistofachambercapabletokeepthespecifiedtesttemperaturewithinthespecifiedtolerance,thepowersupplycapabletogeneratethespecifiedACorDCvoltages,andtheboardtomakeelectricalcontacttotheterminalsofdevicesundertestwithsocketorothermountingmethod,havingheat.
2.1Circuitry
Thebiasingandoperatingschemesshallconsiderthelimitationsofthedevice.Devicethermalcharacterizationshallbeconsideredtoensurethatthetemperatureof”HotSpots”onthediedoesnotexceedmaximumratedjunctiontemperature(Tjmax).
2.2Devicemounting
Devicemountingshallconsiderthethermalcapacitytominimizeadverseeffectsduringtest.
Remarks:
WhenheSMDismountedonthetestboardforevaluation,therelevantconditions(substratematerial,landsize,solderingmethod,fluxcleaning,etc.)shouldbespecifiedintherelevantspecifications.
2.3Environmentalchamber
Theenvironmentalchambershallbecapableofmaintainingthespecifiedambienttemperaturewithinatoleranceof±5°Cthroughoutthechamberwhileatestisbeingconducted.
3.PROCEDURE
3.1Initialmeasurement
Theinitialmeasurementsshouldbecarriedoutinconformitywiththeitemsandconditionsspecifiedinrelevantspecifications.
3.2Operatingmodeandtestcircuit
Operatingmodeandtestcircuitshouldbeinconformitywiththestipulationsoftherelevantspecifications.
(1)High-TemperatureOperatingLife(HTOL)
TheHTOLtestisconfiguredtoexercisethemaximumnumberofnodesfeasible.Thesupplyvoltagesandclockfrequencyshouldbeinconformitywiththestipulationsoftherelevantspecifications.
(2)High-TemperatureReverse-Bias(HTRB)
TheHTRBtestisconfiguredtoapplythemaximumratedDCreversevoltage(VRMAX)[/quote]
购买了付费内容
请问楼主有IEC 60749 全家桶吗
购买了付费内容
购买了付费内容
购买了付费内容
购买了付费内容
十分有用
谢谢分享
:lol:lol:lol:lol:lol
:)./……….
好多标准啊,请问EIAJED-4701-B123是在100里面吗?我下载下来看看:)
我都需要呀,谢谢了
有没有103105之类的?
谢谢你的慷慨
这是什么标准?在哪里能找到
感谢!现在要做日本的POS,就是想找这些资料学习下!
感谢!ddddddddddddddddddd
谢啦!
非常感謝~
非常感謝LZ的分享!
xiexieluo
找到了正需要用的标准,多谢楼主:)
不错,都是能下载的资料,感谢LZ的无私奉献。(今天正好在找这些标准)
谢谢楼主!!!
好东西,谢谢楼主!
这个标准找了好久了,谢谢楼主分享。
请问各位高手,这些标准里面重点在测试方法、步骤等,有没有(或从哪里能找到)各项测试的测试样品数量信息,以及Accept/SampleSize信息等等。
这个确实不错,真是谢谢楼主了。
大大我也好想要一份
e-mail:cingchang@hotmail.com
謝謝
附件無法下載啊!!
能否發到[email]chenhaojue.333@163.com[/email]
[size=5][color=blue]site:tsc.jeita.or.jp/tsc/standardfiletype:pdf
[[i]本帖最后由adda于2007-9-2714:30编辑[/i]]
LZ资料好多!羡慕死了!你家隔壁是中国标准仓库吗?:lolLZ强悍死了!非常热心!
ED-4701_500
EIAJED-4701/400
[quote]
Environmentalandendurancetestmethodsfor
semiconductordevices(StresstestI)
TESTMETHOD301
RESISTANCETOSOLDERINGHEATSURFACEMOUNTINGDEVICES(SMD)
1.SCOPE
ThisstandardprovidesforthemethodtoevaluatetosolderingheatofSMDusedinelectronicequipmentforconsumerapplicationandindustrialapplicationingeneral.
2.TESTEQUIPMENT
2.1Hightemperaturefurnace
ThehightemperaturefurnacemustbecapableofkeepingtemperaturespecifiedinSub-clause4.2forlongtime.
2.2Moisturechamber
ThemoisturechambermustbecapableofkeepingtemperatureandrelativehumidityspecifiedinSub-clause4.2forlongtime.Thematerialcomposingthechambermustnotreactunderhighhumidityconditions.Watertobeusedinthetestsmustbedistilledwaterordeionizedwater,withpHfrom6.0to7.2andresistivityof500Wmormoreat23°C.
2.3Infraredreflowsoldering/ConvectionreflowsolderingfurnaceTheinfraredandtheconvectionreflowsolderingfurnacemustbecapabletomeetthetemperatureprofilespecifiedinSub-clause4.4(1).Thetemperatureprofileisspecifiedintermsofthetemperatureoftopsurfaceofthespecimenplacedontheholder(refertoSub-clause2.7).Thetemperatureatthe
topsurfaceofthespecimenshallbemeasuredasshowninFigure1.
Figure1Methodofmeasuringthetemperatureprofileofaspecimen
2.4Vaporphasereflowsolderingfurnace
ThevaporphasereflowsolderingfurnacemustbecapabletomeetthetemperatureprofilespecifiedinSub-clause4.4(2).Thetemperatureprofileisspecifiedintermsofthetemperatureoftopsurfaceofthespecimenplacedontheholder(refertoSub-clause2.7).ThetemperatureatthetopsurfaceofthespecimenshallbemeasuredasshowninFigure1.
2.5Wavesolderingfurnace
ThewavesolderingfurnacemustbecapableofkeepingtemperatureofmoltensolderduringthesolderheatingspecifiedinSub-clause4.4(3).Themoltensoldermustalwaysbeflowed.ThepreheatconditionsinSub-clause4.4(3)(b)arespecifiedintermsofthetemperatureatthetopsurfaceofthespecimenasshowninFigure1.
EIAJED-4701/300kekaoxing.com
2.6Solderbath
ThesolderbathshouldhavecapacityenoughtokeepthetemperatureofmoltensolderwithintheprescribedvaluesevenduringthesolderheatingdescribedinSub-clause4.4(4).ThedippingequipmentshouldbecapabletocontrolthedippingdepthandthedippingtimeoftheterminalsinthemoltensolderasspecifiedinSub-clause4.4(4)(c).
2.7Holders
Unlessotherwisespecified,thematerialoftheholder,whichthespecimenistobeplacedonduring
thesolderheatinginthereflowsolderingandthewavesolderingfurnace,shouldbemadefromglassreinforced
epoxyresin,polyimide,oraluminasubstrate
3.MATERIALS
3.1Perfluorocarbon
UsePerfluorocarbon(perfluoroisobutyrene)orequivalentinvaporphasereflowsolderingfurnaces.
3.2Solder
SolderstobeusedinthistestshouldbethoseonesspecifiedinH60A,H60S,H63AofJISZ3282(SOLDER)orinAPPENDIXBofJISC0050.
3.3Flux
Fluxtobeusedinthistestshouldbe2-propanol(JISK8839)orethanol(ethylalcohol,JISK8101)solutionofrosin(JISK5902)(theconcentrationshouldbefrom10%to35%ofrosinintermsofmassratio,and25%unlessotherwisespecified)orthematerialspecifiedinAPPENDIXCofJISC0050.[/quote]
[quote]
Environmentalandendurancetestmethodsfor
semiconductordevices
(LifetestII)
EstablishedinAugust,2001
Preparedby
TechnicalStandardizationCommitteeonSemiconductorDevices
Publishedby
JapanElectronicsandInformationTechnologyIndustriesAssociation
11,KandaSurugadai3-chome,Chiyoda-ku,Tokyo101-0062,Japan
PrintedinJapan
EIAJED-4701/200
StandardofJapanElectronicsandInformationTechnologyIndustriesAssociationEnvironmentalandendurancetestmethodsforsemiconductordevices(LifetestII)
1.SCOPE
Thesestandardsprovideforenvironmentaltestmethodsandendurancetestmethods(especiallylifetests)aimedatevaluatingtheresistanceandtheenduranceofdiscretesemiconductordevicesandintegratedcircuits(hereinaftergenericallycalledsemiconductordevices)usedinelectronicequipmentmainlyforgeneralindustrialapplicationsandconsumerapplications,underthevariousenvironmentalconditionsofvariouskindsthatoccurduringtheiruse,storageandtransportation.
2.DEFINITIONOFTERMS
ThedefinitionsofthetechnicaltermsusedinthesestandardsandintherelevantspecificationsaregiveninEIAJED-4701/001″Environmentalandendurancetestmethodsforsemiconductordevices(General).”
3.PRECAUTIONS
TheprecautionsusedinthesestandardsandintherelevantspecificationsaregiveninEIAJED-4701/001″Environmentalandendurancetestmethodsforsemiconductordevices(General).”
4.TESTMETHODS
RefertotheAppendixforthetestmethods.
Remarks:
Thevarioustestmethodsarearrangedindependentlyforthesakeofmoreconvenientuseofthesestandards.[/quote]