这几天做实验,结合标准IEC68-2-1,2-78发现有几个问题:
1,关于高/低温测试,2-1Ab:描述:看这个描述,是先升温,chamber温度达到要求时,样品才能poweron,不知道大家平时怎么做的?
我看到不少厂商是把样品放进去就poweron,温度还没有达到要求。
Thespecimenisintroducedintothechamberwhichisatthetemperatureofthelaboratory.
Thetemperatureisthenadjustedtothetemperatureappropriatetothedegreeofseverity,as
specifiedintherelevantspecification.Aftertemperaturestabilityofthetestspecimenhas
beenreached,thespecimenisexposedtotheseconditionsforthespecifiedduration.
Forspecimensthatarerequiredtobeoperational(eventhoughtheydonotmeetthe
requirementsofbeingheatdissipating),[color=Red]powershallthenbeappliedtothespecimenanda
functionaltestisperformedasnecessary.
2.对于高温高湿测试,2-78:为了避免产品表面凝露,一般要求先升高温度,再开湿度,以避免凝露。如果我们用的是恒温恒湿箱,可能直接设定相应的温度和湿度点,就开始运行,设备可以保证是温度向上升,然后再是湿度上升吗?chamber厂商是怎么按:2-78的要求确保凝露不发生呢?
2-78:
b)Adjustthetemperatureinthechambertotheprescribedseverity,andallowthespecimen
toreachtemperaturestability.
c)Condensationcanbeavoidedduringthisperiodbynotincreasingtheabsolutehumidity.
d)Adjustthehumiditytotheprescribedseveritywithinatimeofnotmorethan2h.
[quote]chriswang发表于2014-1-616:59[url=pid=139602&ptid=15221][/url]
凝露好像要用风对着吹[/quote]
应该不用风吹吧
凝露好像要用风对着吹
先开恒温高温再开湿热不就成了;P
怎么操作试验箱看你要的效果,你做的试验是不是要凝露的,关键在这。
[quote]可靠性菜鸟发表于2014-1-218:19[url=pid=139498&ptid=15221][/url]
先升温度,再升湿度,可以避免凝露产生;
我们用爱斯佩克的箱子,还有东之旭的。
[/quote]
还是你们先进都espec的
我们还是国产牌子没办法分开设置,无语
先升温度,再升湿度,可以避免凝露产生;
我们用爱斯佩克的箱子,还有东之旭的。
设程序的时候,温度跟湿度是可以分开设置的,既,分开跑的,温度达到之后,才跑下一个程序
[quote]可靠性菜鸟发表于2014-1-216:48[url=pid=139488&ptid=15221][/url]
我们平时坚持先升温度,再升湿度;先降湿度,再降温度。
坐过一个日本的客户,但他们就坚持同时升温湿度,…[/quote]
如果我们用的是恒温恒湿箱,可能直接设定相应的温度和湿度点,就开始运行,设备可以保证是温度先上升,然后再是湿度上升吗?chamber厂商是怎么按:2-78的要求确保凝露不发生呢?
大家是怎么做到先升温度再升湿度,先降湿度,再降温呢?因为大部分是在恒温恒湿箱设定温湿度,或是设定测试程序,机器自动运行?这个过程大家是怎么知道温湿度升降的顺序呢?
还有,之所以会产生凝露,是因为样品表面的温度比较低
我们平时坚持先升温度,再升湿度;先降湿度,再降温度。
坐过一个日本的客户,但他们就坚持同时升温湿度,同时降温湿度。
大部分客户都要求等环境温度稳定后,再POWERON。