EIAJ ED-4701/100~500
EIAJED-4701系列标准StandardofJapanElectronicsandInformationTechnologyIndustriesAssociation
EIAJED-4701/100
Environmentalandendurancetestmethodsfor
semiconductordevices
(LifetestI)
EIAJED-4701/100
TESTMETHOD101
STEADYSTATEOPERATINGLIFE
1.SCOPE
Thisstandardprovidesforthemethodtoevaluatetheenduranceofsemiconductordeviceswhentheyaresubmittedtoelectricstressandthermalstressoflongduration.
Remarks:
Caremustbetakenwhenexecutingthistest,becausethedevicetemperaturemayexceedtheambientpresettemperatureandriseconspicuouslyduetointernallydissipatedheatfromthedevice.
2.TESTEQUIPMENT
Equipmenttobeusedinthistestshouldconsistofachambercapabletokeepthespecifiedtesttemperaturewithinthespecifiedtolerance,thepowersupplycapabletogeneratethespecifiedACorDCvoltages,andtheboardtomakeelectricalcontacttotheterminalsofdevicesundertestwithsocketorothermountingmethod,havingheat.
2.1Circuitry
Thebiasingandoperatingschemesshallconsiderthelimitationsofthedevice.Devicethermalcharacterizationshallbeconsideredtoensurethatthetemperatureof"HotSpots"onthediedoesnotexceedmaximumratedjunctiontemperature(Tjmax).
2.2Devicemounting
Devicemountingshallconsiderthethermalcapacitytominimizeadverseeffectsduringtest.
Remarks:
WhenheSMDismountedonthetestboardforevaluation,therelevantconditions(substratematerial,landsize,solderingmethod,fluxcleaning,etc.)shouldbespecifiedintherelevantspecifications.
2.3Environmentalchamber
Theenvironmentalchambershallbecapableofmaintainingthespecifiedambienttemperaturewithinatoleranceof±5°Cthroughoutthechamberwhileatestisbeingconducted.
3.PROCEDURE
3.1Initialmeasurement
Theinitialmeasurementsshouldbecarriedoutinconformitywiththeitemsandconditionsspecifiedinrelevantspecifications.
3.2Operatingmodeandtestcircuit
Operatingmodeandtestcircuitshouldbeinconformitywiththestipulationsoftherelevantspecifications.
(1)High-TemperatureOperatingLife(HTOL)
TheHTOLtestisconfiguredtoexercisethemaximumnumberofnodesfeasible.Thesupplyvoltagesandclockfrequencyshouldbeinconformitywiththestipulationsoftherelevantspecifications.
(2)High-TemperatureReverse-Bias(HTRB)
TheHTRBtestisconfiguredtoapplythemaximumratedDCreversevoltage(VRMAX) 还是sunjj资料多,一有朋友求助,在你这里几乎都给帮上忙。。:victory:
EIAJ ED-4701/200
Environmentalandendurancetestmethodsfor
semiconductordevices
(LifetestII)
EstablishedinAugust,2001
Preparedby
TechnicalStandardizationCommitteeonSemiconductorDevices
Publishedby
JapanElectronicsandInformationTechnologyIndustriesAssociation
11,KandaSurugadai3-chome,Chiyoda-ku,Tokyo101-0062,Japan
PrintedinJapan
EIAJED-4701/200
StandardofJapanElectronicsandInformationTechnologyIndustriesAssociationEnvironmentalandendurancetestmethodsforsemiconductordevices(LifetestII)
1.SCOPE
Thesestandardsprovideforenvironmentaltestmethodsandendurancetestmethods(especiallylifetests)aimedatevaluatingtheresistanceandtheenduranceofdiscretesemiconductordevicesandintegratedcircuits(hereinaftergenericallycalledsemiconductordevices)usedinelectronicequipmentmainlyforgeneralindustrialapplicationsandconsumerapplications,underthevariousenvironmentalconditionsofvariouskindsthatoccurduringtheiruse,storageandtransportation.
2.DEFINITIONOFTERMS
ThedefinitionsofthetechnicaltermsusedinthesestandardsandintherelevantspecificationsaregiveninEIAJED-4701/001"Environmentalandendurancetestmethodsforsemiconductordevices(General)."
3.PRECAUTIONS
TheprecautionsusedinthesestandardsandintherelevantspecificationsaregiveninEIAJED-4701/001"Environmentalandendurancetestmethodsforsemiconductordevices(General)."
4.TESTMETHODS
RefertotheAppendixforthetestmethods.
Remarks:
Thevarioustestmethodsarearrangedindependentlyforthesakeofmoreconvenientuseofthesestandards.
EIAJ ED-4701/300
Environmentalandendurancetestmethodsfor
semiconductordevices(StresstestI)
TESTMETHOD301
RESISTANCETOSOLDERINGHEATSURFACEMOUNTINGDEVICES(SMD)
1.SCOPE
ThisstandardprovidesforthemethodtoevaluatetosolderingheatofSMDusedinelectronicequipmentforconsumerapplicationandindustrialapplicationingeneral.
2.TESTEQUIPMENT
2.1Hightemperaturefurnace
ThehightemperaturefurnacemustbecapableofkeepingtemperaturespecifiedinSub-clause4.2forlongtime.
2.2Moisturechamber
ThemoisturechambermustbecapableofkeepingtemperatureandrelativehumidityspecifiedinSub-clause4.2forlongtime.Thematerialcomposingthechambermustnotreactunderhighhumidityconditions.Watertobeusedinthetestsmustbedistilledwaterordeionizedwater,withpHfrom6.0to7.2andresistivityof500Wmormoreat23°C.
2.3Infraredreflowsoldering/ConvectionreflowsolderingfurnaceTheinfraredandtheconvectionreflowsolderingfurnacemustbecapabletomeetthetemperatureprofilespecifiedinSub-clause4.4(1).Thetemperatureprofileisspecifiedintermsofthetemperatureoftopsurfaceofthespecimenplacedontheholder(refertoSub-clause2.7).Thetemperatureatthe
topsurfaceofthespecimenshallbemeasuredasshowninFigure1.
Figure1Methodofmeasuringthetemperatureprofileofaspecimen
2.4Vaporphasereflowsolderingfurnace
ThevaporphasereflowsolderingfurnacemustbecapabletomeetthetemperatureprofilespecifiedinSub-clause4.4(2).Thetemperatureprofileisspecifiedintermsofthetemperatureoftopsurfaceofthespecimenplacedontheholder(refertoSub-clause2.7).ThetemperatureatthetopsurfaceofthespecimenshallbemeasuredasshowninFigure1.
2.5Wavesolderingfurnace
ThewavesolderingfurnacemustbecapableofkeepingtemperatureofmoltensolderduringthesolderheatingspecifiedinSub-clause4.4(3).Themoltensoldermustalwaysbeflowed.ThepreheatconditionsinSub-clause4.4(3)(b)arespecifiedintermsofthetemperatureatthetopsurfaceofthespecimenasshowninFigure1.
EIAJED-4701/300kekaoxing.com
2.6Solderbath
ThesolderbathshouldhavecapacityenoughtokeepthetemperatureofmoltensolderwithintheprescribedvaluesevenduringthesolderheatingdescribedinSub-clause4.4(4).ThedippingequipmentshouldbecapabletocontrolthedippingdepthandthedippingtimeoftheterminalsinthemoltensolderasspecifiedinSub-clause4.4(4)(c).
2.7Holders
Unlessotherwisespecified,thematerialoftheholder,whichthespecimenistobeplacedonduring
thesolderheatinginthereflowsolderingandthewavesolderingfurnace,shouldbemadefromglassreinforced
epoxyresin,polyimide,oraluminasubstrate
3.MATERIALS
3.1Perfluorocarbon
UsePerfluorocarbon(perfluoroisobutyrene)orequivalentinvaporphasereflowsolderingfurnaces.
3.2Solder
SolderstobeusedinthistestshouldbethoseonesspecifiedinH60A,H60S,H63AofJISZ3282(SOLDER)orinAPPENDIXBofJISC0050.
3.3Flux
Fluxtobeusedinthistestshouldbe2-propanol(JISK8839)orethanol(ethylalcohol,JISK8101)solutionofrosin(JISK5902)(theconcentrationshouldbefrom10%to35%ofrosinintermsofmassratio,and25%unlessotherwisespecified)orthematerialspecifiedinAPPENDIXCofJISC0050. EIAJED-4701/400 ED-4701_500 LZ资料好多!羡慕死了!你家隔壁是中国标准仓库吗?:lolLZ强悍死了!非常热心! site:tsc.jeita.or.jp/tsc/standardfiletype:pdf