坦白的讲,对于定时定量测试计算MTBF不是很好;
由于限制,附件没办法上传,贴一下阿氏模型,大家将就一下。
AF(AccelerationFactor)=exp[Ea/B(1/Tu-1/Ta)] 46.52 DegreeC
Tu(NormalOperationTemperature,oK) 308 35
Ta(AcceleratingTemperature,oK) 353 80
Ea(ActivationEnergy,eV) 0.80
B(Boltzman'sConstant,eV/oK) 8.6230000E-05
1/Tu-1/Ta 4.1389206E-04
Ea/B 9.2775136E+03
Ea/B(1/Tu-1/Ta) 3.8398892
MTBF= 92032 10.51
T:Totalaccumulatedtesttime 4560
SampleNumber 10
Day 19.0
C:ConfidenceLevel 90.00%
R:FaiulreNumber 0
2TxAF 424265.3149281 FailureNumber
X2(1-C,2R+2) 4.61 0
7.78 1
10.64 2 |
|